Instrument introduction

Gas chromatograph is a kind of high-precision scientific instrument for the analysis and detection of various components in mixed gas. It uses nitrogen, hydrogen, helium, argon and other gases as carrier gases to carry out qualitative and quantitative analysis of various components in mixed gas.

The chromatograph (button type) is an economical and practical gas chromatograph developed by Tate instruments. It adopts the control system of "LCD + button", and the interface operation is simple and intuitive, which is convenient for users.

This instrument is widely used in scientific research and education, petroleum, chemical industry, biochemistry, food safety, medicine and health, environmental monitoring, judicial investigation and other fields. The instrument has high precision, good repeatability and is reliable.

 
Instrument features

1. Compared with the previous generation YJJ-208, the production process has been improved. The gas source channel and internal structure of the instrument have been redesigned. The distribution and arrangement of parts and components are more reasonable and the structure is more compact. The overall volume of the instrument is smaller than that of gc2020 model, so it is durable.

2. The instrument has high precision, good repeatability and stable performance. The repeatability error of the instrument can reach 1.5%, which is better than 3% of the national standard.

3. The column temperature box adopts a brand-new microcomputer temperature control system with built-in high-sensitivity temperature sensor, which can accurately control the temperature rise and temperature drop through the system. It has six completely independent temperature control systems, and the temperature control accuracy reaches ± 0.1 ℃. It can realize 16 step temperature programming, which enables the equipment to be competent for large-scale sample analysis; the column box is equipped with automatic back door opening system, which can improve the low temperature control accuracy and speed up / down temperature;

4. The whole machine adopts modular design and can work in parallel with multiple processors,. It includes two kinds of injection port modules (capillary column injection port and packed column injection port), five kinds of high-performance detector modules (FID, TCD, ECD, FPD and NPD). According to customer requirements, a variety of injection ports and detector modules can be installed (six way valve, ten way valve gas injector, headspace injector, thermal analysis injector, cracking furnace injector, methane reformer) can be installed according to customer requirements, and the maximum support of three groups of injection Port and 4 kinds of detectors, convenient for users to upgrade.

5. The instrument has the function of computer reverse control, which can be directly connected with the computer. The instrument can be operated through the network version chromatographic workstation software independently developed by our company (the maximum support is 253 sets). The temperature rise and temperature drop of the injection port, column temperature box and detector of the instrument can be controlled by program. Under the condition that the customer is equipped with an automatic injection valve (or an automatic injector), the system can realize unattended instrument, automatic temperature rising and ignition, automatic loading method, automatic calculation of test results and other test procedures, meeting the requirements of online monitoring.

6. Instrument configuration, built-in IP protocol stack, test data can be uploaded to the computer of field laboratory, department head and superior leader through enterprise LAN or Internet, which is convenient for each department to monitor the operation and test results of instrument in real time. It can connect with manufacturers directly through the Internet to realize remote diagnosis and remote program update of gas chromatograph.

7. It can be connected with the automatic injector produced by many domestic and foreign manufacturers, such as aoc-20i of Shimadzu and HT series of high-efficiency gas-phase liquid automatic injector of HTA company in Italy, etc., which can reduce the detection error of the instrument caused by human factors and improve the test accuracy of the instrument.

 
Technical data
 

Model

 YJJ-308

Repeatability error of test results

1.5%

Communication interface

Configure standard network interface output (type 6 network cable connection), support RS-232 output (optional)

Host size

510×500×540mm

Power

AC220V±10%  50Hz   2500W

Work environment

Ambient temperature: 5 ~ 35 ℃, relative humidity: ≤ 85%, no corrosive gas in the room, stable working table, no strong magnetic field around

Related accessories

Detector (matching according to user requirements)

Hydrogen flame ionization detector (FID)

Thermal conductivity cell detector (TCD)

Electron capture detector (ECD)

Flame photometric detector (FPD)

Nitrogen and phosphorus detector (NPD)

Autosampler (optional)

Shimadzu AOC-20i

HTA company's HT series high efficiency automatic gas liquid injector

Column oven

Furnace size

280×300×180mm

Temperature range

Indoor +5~400

Temperature setting

1˚C;Program heating rate 0.1˚C

Temperature stability of chromatographic column

0.01˚C at ambient temperature change 1˚C

Stage

16 stage

Rate of rise

0.1-50/min(rising 0.1℃)

Hydrogen flame ionization detector(FID

Maximum operating temperature

400

Detection limit

5×10-12g/s   [n-C16]

Drift

5×10-13A/30min

Noise

2×10-13A

Dynamic linear range

107

Thermal conductivity cell detector(TCD

Maximum operating temperature

400

Sensitivity

≥6000mv.ml/mg   [benzene / toluene]

Drift

100uV/30mi

Noise

20uV

Dynamic linear range

104

Electron capture detector(ECD

Maximum operating temperature

350

Sensitivity

1×10-14g/ml    (γ-666

Drift

50uV/30min

Noise

20uV

Dynamic linear range

104

Flame photometric detector(FPD

Maximum operating temperature

250

Sensitivity

2×10-13g/sP     5×10-11g/sS

Drift

4×10-11A/30min

Noise

2×10-12A

Dynamic linear range

103P      102S

Nitrogen and phosphorus detector(NPD)

Maximum operating temperature

400

Sensitivity

5×10-13g/sP       1×10-12g/sN

Drift

25×10-12A/30min

Noise

4×10-13A

Dynamic linear range

103P           103N

 
 
Base Configuration 
 
Name
Qty
Description
Remarks
Host
1
Network reverse control chromatograph, 7-inch color touch screen, large volume column oven design, integrated vaporizer design, double column and double gas path, double steady flow design, microcomputer temperature control, real-time display of six temperature control, temperature rise state, network (up to 253 channels) digital signal output, fault self-test, overheat protection, timing switch on and off, removable quartz high-temperature nozzle, 30 stage 31 platform temperature program Automatic double back door opening system (can connect multiple external events, suitable for real-time online monitoring), automatic ignition
 
Chromatographic injector
1
Packed column injector
For microinjector injection
High sensitivity detector
3
FID detector 2sets,TCD detector 1set(Multiple magnification)
 
Special chromatographic column for determination of transformer oil
3
One test H2、CO、CO2;
One test CH4、C2H4、C2H6、C2H2;
One for TCD reference gas
Neutral or weak polarity
Ni Reformer
1
Convert trace CO, CO2 into CH4 and respond in FID
 
Fully automatic oscillator
1
For sample oil and gas collection
 
Standard gas
1
7-component dissolved gas, 4L, including pressure relief valve
 
Accessories
1
200 small rubber caps, 10 pieces for 5ml & 100ml glass syringe, 2 pcs for 1ml glass syringes, 1 Quantitative card and 1 box of stainless steel needles
 
Special chromatographic workstation for transformer oil
1
Used for chromatograph control and data communication
Digital signal communication, various parameter setting of computer counter control chromatograph
Computers and printers
1
Windows XP or win7, 32-bit system
Hydrogen generator
1
High purity hydrogen (up to 99.995%) is produced
Hydrogen cylinders (including pressure relief valves) can also be purchased
Air generator
1
Three stage oil-free compressed air is produced
Air cylinders (including pressure relief valve) can also be purchased
Nitrogen cylinder and pressure reducing valve
1
99.999% Nitrogen 40L
 