Transformer Oil Dissolved Gas Analyzer

Transformer Oil Dissolved Gas Analyzer Transformer Oil Dissolved Gas Analyzer Transformer Oil Dissolved Gas Analyzer
Product name:Transformer Oil Dissolved Gas Analyzer
Item:YJJ-401
Details:
Brief introduction
 
YJJ-401 Gas chromatograph smart (intelligent) is an intelligent Internet of things gas chromatograph developed and produced by our company on the basis of YJJ-309 platform according to our own IOT chromatograph technology. The electronic gas path control system is used to replace the mechanical pressure reducing valve. The system program can accurately control the pressure and flow of carrier gas, hydrogen and air through the electronic gas path control unit (EPC / AFC), In the case of configuration of automatic sampler and other supporting equipment, mobile phones, tablet computers, laptops can be used to remotely control the operation of the whole equipment through wireless network, so as to truly realize unattended operation of the instrument.
 
Instrument features

1. New production process, redesigning the air source channel and internal structure in the instrument, making the layout of parts more reasonable, reducing signal interference of components, improving detection accuracy, and excellent stability and durability of the equipment.

2. It adopts 7-inch color touch screen control and professional chromatograph UI operation interface design, which can directly reflect the internal temperature value of injection port, column temperature box and detector, and the values of each detector, as well as the running time. It has the function of one key cooling. The user can set the detection conditions by himself, which is convenient for use.

3. The electronic gas path control system is used to replace the mechanical pressure reducing valve, and the pressure and flow rate of the three gases of hydrogen carrying air are accurately controlled by the system program through the electronic gas path control unit (EPC / AFC), so as to improve the repeatability of the equipment. The repeatability error of the instrument test can reach 1.5%, which is better than the national standard of 3%.

4. The column temperature box adopts six independent temperature control system, automatic back door opening system, 30 stage 31 platform temperature programmed, fast rising / cooling speed, and temperature control accuracy of 0.1 ℃, which makes the equipment competent for large-scale sample analysis.

5. The whole machine adopts modular design and can work in parallel with multiple processors. It includes two kinds of injection port modules (capillary column injection port and packed column injection port), five kinds of high-performance detector modules (FID, TCD, ECD, FPD and NPD). According to customer requirements, a variety of injection ports and detector modules can be installed (six way valve, ten way valve gas injector, headspace injector, thermal analysis injector, cracking furnace injector, methane reformer) can be installed according to customer requirements, and the maximum support of three groups of injection Port and 4 kinds of detectors, convenient for users to upgrade.

6. It can be directly connected with the computer, and can be operated by PC terminal network edition chromatography workstation software (maximum support 253 sets), and realize the temperature rising and cooling of instrument injection port, column temperature box and detector by program control. Under the condition that the customer is equipped with an automatic injection valve (or an automatic injector), it can realize some test procedures such as unattended instrument, automatic temperature rising and ignition, automatic loading method, automatic calculation of test results, etc., meeting the requirements of online test.

7. Exclusive Internet of things chromatograph technology, built-in IP protocol stack, can upload test data to the computer of field laboratory, department head and superior leader through enterprise LAN or Internet, so as to facilitate each department to monitor the operation and test results of the instrument in real time. It can connect with manufacturers directly through the Internet to realize remote diagnosis and remote program update of gas chromatograph.

8. It can be connected with the automatic injector produced by many domestic and foreign manufacturers, such as aoc-20i of Shimadzu and HT series of high-efficiency gas-phase liquid automatic injector of HTA company in Italy, etc., which can reduce the detection error of the instrument caused by human factors and improve the test accuracy of the instrument.

 
Technical data
 
 
Model
YJJ-401
Temperature control
Above room temperature4— 450℃,
Liquid nitrogen refrigeration for optional:-80℃-400℃
Accuracy of column oven temperature control
±0.02℃
Display accuracy
0.1℃
Column oven rising rate
30 stage 31 platform temperature programming, 0-40 ℃ / min (adjustment increment 0.1 ℃ / min) up to 80 ℃ / min
Temperature programmed repeatability
≤1%
TCD Detector sensitivity
S value≥15000mv.ml/mg(benzene)
Baseline drift
≤30uv/30min
Baseline noise
≤10uv
FID Detection limit
≤3×10-12g/s(Cetane)
Baseline drift
≤1×10-13 A/30min
Baseline noise
≤5×10-14A/30min
Automation Engineering
It can be added: automatic injector connection, four ways flow pressure display functions; Anti-control workstation for optional
 
 
Measurement index of transformer oil
 

Minimum detection limit of gas in transformer oil (unit: uL / L)

H2
CO
CH4
CO2
C2H4
C2H6
C2H2
≤1.5
≤2
≤0.05
≤5
≤0.05
≤0.05
≤0.05
 

(Better than national standard)

 
Base Configuration 
 
Name
Qty
Description
Remarks
Host
1
Network reverse control chromatograph, 7-inch color touch screen, large volume column oven design, integrated vaporizer design, double column and double gas path, double steady flow design, microcomputer temperature control, real-time display of six temperature control, temperature rise state, network (up to 253 channels) digital signal output, fault self-test, overheat protection, timing switch on and off, removable quartz high-temperature nozzle, 30 stage 31 platform temperature program Automatic double back door opening system (can connect multiple external events, suitable for real-time online monitoring), automatic ignition
 
Chromatographic injector
1
Packed column injector
For microinjector injection
High sensitivity detector
3
FID detector 2sets,TCD detector 1set(Multiple magnification)
 
Special chromatographic column for determination of transformer oil
3
One test H2、CO、CO2;
One test CH4、C2H4、C2H6、C2H2;
One for TCD reference gas
Neutral or weak polarity
Ni Reformer
1
Convert trace CO, CO2 into CH4 and respond in FID
 
Fully automatic oscillator
1
For sample oil and gas collection
 
Standard gas
1
7-component dissolved gas, 4L, including pressure relief valve
 
Accessories
1
200 small rubber caps, 10 pieces for 5ml & 100ml glass syringe, 2 pcs for 1ml glass syringes, 1 Quantitative card and 1 box of stainless steel needles
 
Special chromatographic workstation for transformer oil
1
Used for chromatograph control and data communication
Digital signal communication, various parameter setting of computer counter control chromatograph
Computers and printers
1
Windows XP or win7, 32-bit system
Hydrogen generator
1
High purity hydrogen (up to 99.995%) is produced
Hydrogen cylinders (including pressure relief valves) can also be purchased
Air generator
1
Three stage oil-free compressed air is produced
Air cylinders (including pressure relief valve) can also be purchased
Nitrogen cylinder and pressure reducing valve
1
99.999% Nitrogen 40L
 
←[Previous:YJJ-308] [Next:YJJ-309]→